<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Biopsy &#8211; RSTI Exchange &#8211; Engineered for Life™</title>
	<atom:link href="https://rsti-exchange.com/modalities/biopsy/feed/" rel="self" type="application/rss+xml" />
	<link>https://rsti-exchange.com</link>
	<description>Pre-owned radiological Equipment &#38; Medical Imaging Parts</description>
	<lastBuildDate>Fri, 02 Oct 2015 15:16:57 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.6.2</generator>
	<item>
		<title>Lorad Multicare Biopsy System</title>
		<link>https://rsti-exchange.com/products/delta-32-biopsy-system/</link>
					<comments>https://rsti-exchange.com/products/delta-32-biopsy-system/#respond</comments>
		
		<dc:creator><![CDATA[editor one]]></dc:creator>
		<pubDate>Fri, 02 Oct 2015 14:57:52 +0000</pubDate>
				<guid isPermaLink="false">https://rsti-exchange.com/?post_type=products&#038;p=3315</guid>

					<description><![CDATA[Lorad Multicare Biopsy System S/N: 8411020194 Nov 2002 &#160; Inventory &#160; Multicare Biopsy Table w/table top &#38; cushions Detector w/defect disc (2001) X-ray Tube (2001) Footswitch Assy DSM Workstation Monitor Keyboard &#38; Mouse DSM Computer (Windows NT) w/DICOM Print DSM &#8230; <a href="https://rsti-exchange.com/products/delta-32-biopsy-system/">Read more<span class="meta-nav">&#8230;</span></a>]]></description>
										<content:encoded><![CDATA[<p>Lorad Multicare Biopsy System</p>
<p>S/N: 8411020194</p>
<p>Nov 2002</p>
<p>&nbsp;</p>
<p><strong><u>Inventory</u></strong></p>
<p>&nbsp;</p>
<p>Multicare Biopsy Table w/table top &amp; cushions</p>
<ul>
<li>Detector w/defect disc (2001)</li>
<li>X-ray Tube (2001)</li>
<li>Footswitch Assy</li>
</ul>
<p>DSM Workstation</p>
<ul>
<li>Monitor</li>
<li>Keyboard &amp; Mouse</li>
<li>DSM Computer (Windows NT) w/DICOM Print</li>
<li>DSM Table w/power supply</li>
</ul>
<p>Generator</p>
<p>3 Compression Paddles</p>
<p>Calibration tools &amp; Phantom</p>
<p>Manuals</p>
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rsti-exchange.com/products/delta-32-biopsy-system/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Siemens OPDIMA Biopsy System (Parts)</title>
		<link>https://rsti-exchange.com/products/siemens-opdima-biopsy-system-parts/</link>
					<comments>https://rsti-exchange.com/products/siemens-opdima-biopsy-system-parts/#respond</comments>
		
		<dc:creator><![CDATA[editor one]]></dc:creator>
		<pubDate>Fri, 31 Jan 2014 19:06:13 +0000</pubDate>
				<guid isPermaLink="false">https://rsti-exchange.com/?post_type=products&#038;p=2492</guid>

					<description><![CDATA[Siemens OPDIMA Biopsy System S/N: 3734 Mar 2002 &#160; INVENTORY   Biopsy Unit (AS 00) Model: 62 93 588 X041E S/N: 3734 Mar 2002 &#160; OPDIMA Biopsy Controller Model: 64 30 305 X044E S/N: 1367 Mar 2002 &#160; OPDIMA CCD &#8230; <a href="https://rsti-exchange.com/products/siemens-opdima-biopsy-system-parts/">Read more<span class="meta-nav">&#8230;</span></a>]]></description>
										<content:encoded><![CDATA[<p>Siemens OPDIMA Biopsy System</p>
<p>S/N: 3734</p>
<p>Mar 2002</p>
<p>&nbsp;</p>
<p><b>INVENTORY</b></p>
<p><span style="text-decoration: underline;"> </span></p>
<p><span style="text-decoration: underline;">Biopsy Unit (AS 00)</span></p>
<ul>
<li>Model: 62 93 588 X041E</li>
<li>S/N: 3734</li>
<li>Mar 2002</li>
</ul>
<p>&nbsp;</p>
<p><span style="text-decoration: underline;">OPDIMA Biopsy Controller</span></p>
<ul>
<li>Model: 64 30 305 X044E</li>
<li>S/N: 1367</li>
<li>Mar 2002</li>
</ul>
<p>&nbsp;</p>
<p><span style="text-decoration: underline;">OPDIMA CCD Camera</span></p>
<ul>
<li>Model: 63 97 439 X044E</li>
<li>AST 0</li>
<li>S/N: 1473</li>
<li>May 2002</li>
</ul>
<p><span style="text-decoration: underline;"> </span></p>
<p><span style="text-decoration: underline;">Interconnect cables</span></p>
<p><span style="text-decoration: underline;"> </span></p>
<p><span style="text-decoration: underline;">Sun Monitor</span></p>
<p><span style="text-decoration: underline;"> </span></p>
<p><span style="text-decoration: underline;">Sun Keyboard &amp; Mouse</span></p>
<p><span style="text-decoration: underline;"> </span></p>
<p><span style="text-decoration: underline;">OPDIMA Technical Manual</span></p>
<p><span style="text-decoration: underline;"> </span></p>
<p><b><span style="text-decoration: underline;"> </span></b></p>
<p><b><span style="color: #f9051e;">P  A  R  T  S    U  N  I  T</span></b></p>
<p><b><span style="text-decoration: underline;"> </span></b></p>
<p>Missing:     Sun Computer</p>
<p>                   Calibration Phantom Kit</p>
<p>                   Biopsy Paddle &amp; Needles</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rsti-exchange.com/products/siemens-opdima-biopsy-system-parts/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Lorad Stereoloc</title>
		<link>https://rsti-exchange.com/products/lorad-stereoloc/</link>
					<comments>https://rsti-exchange.com/products/lorad-stereoloc/#respond</comments>
		
		<dc:creator><![CDATA[editor one]]></dc:creator>
		<pubDate>Tue, 25 Jun 2013 15:46:34 +0000</pubDate>
				<guid isPermaLink="false">http://rstiexchange.com/rstipress/?post_type=products&#038;p=966</guid>

					<description><![CDATA[S/N: 20307990102 July 1999  Inventory Cart with Power Supply Monitor DSM Computer Keyboard and Tracball Mouse combination M-IV Biopsy Attachment M-IV CCD Camera 1 Compression Paddle Interconnect Cables  For Stereoloc to attach to M-IV, the M-IV must be fitted with &#8230; <a href="https://rsti-exchange.com/products/lorad-stereoloc/">Read more<span class="meta-nav">&#8230;</span></a>]]></description>
										<content:encoded><![CDATA[<p>S/N: 20307990102</p>
<p>July 1999 </p>
<p><b><span style="text-decoration: underline;">Inventory</span></b></p>
<p>Cart with Power Supply</p>
<p>Monitor</p>
<p>DSM Computer</p>
<p>Keyboard and Tracball Mouse combination</p>
<p>M-IV Biopsy Attachment</p>
<p>M-IV CCD Camera</p>
<p>1 Compression Paddle</p>
<p>Interconnect Cables </p>
<ul>
<li>For Stereoloc to attach to M-IV, the M-IV must be fitted with the Stereoloc attachment package. This is not included.</li>
</ul>
]]></content:encoded>
					
					<wfw:commentRss>https://rsti-exchange.com/products/lorad-stereoloc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Lorad Multicare Platinum</title>
		<link>https://rsti-exchange.com/products/hologic-multicare-platinum/</link>
					<comments>https://rsti-exchange.com/products/hologic-multicare-platinum/#respond</comments>
		
		<dc:creator><![CDATA[editor one]]></dc:creator>
		<pubDate>Tue, 25 Jun 2013 13:10:33 +0000</pubDate>
				<guid isPermaLink="false">http://rstiexchange.com/rstipress/?post_type=products&#038;p=775</guid>

					<description><![CDATA[Lorad Multicare Platinum S/N: 31512051130 December 2005 &#160; Exp. = 5,982 DSM Software Version 3.2.0 Host Software Version 1.0.2 &#160; Inventory   Multicare Platinum Table with Interconnect Cables S/N: 31512051130 Dec 2005 Table Top with Cushions Generator S/N: 31512051130 Dec &#8230; <a href="https://rsti-exchange.com/products/hologic-multicare-platinum/">Read more<span class="meta-nav">&#8230;</span></a>]]></description>
										<content:encoded><![CDATA[<p>Lorad Multicare Platinum</p>
<p>S/N: 31512051130</p>
<p>December 2005</p>
<p>&nbsp;</p>
<ul>
<li>Exp. = 5,982</li>
<li>DSM Software Version 3.2.0</li>
<li>Host Software Version 1.0.2</li>
</ul>
<p>&nbsp;</p>
<p><b><span style="text-decoration: underline;">Inventory</span></b></p>
<p><b><span style="text-decoration: underline;"> </span></b></p>
<p>Multicare Platinum Table with Interconnect Cables</p>
<ul>
<li>S/N: 31512051130</li>
<li>Dec 2005</li>
</ul>
<p>Table Top with Cushions</p>
<p>Generator</p>
<ul>
<li>S/N: 31512051130</li>
<li>Dec 2005</li>
</ul>
<p>DSM Workstation</p>
<ul>
<li>S/N: 6102083928</li>
<li>Feb 2008</li>
<li>18” LCD Monitor</li>
<li>Windows XP</li>
<li>Keyboard &amp; Tracball Mouse</li>
</ul>
<p>AEC Receptor</p>
<p>1 Footswitch</p>
<p>2 Apertures</p>
<p>5 Paddles</p>
<p>Control Keypad</p>
<p>Calibration Needles</p>
<p>Hologic Refurbished Camera</p>
<ul>
<li>S/N: 3200</li>
<li>Feb 2006</li>
</ul>
<p>Manuals</p>
<p style="font-size: 16px; color: #f8061e;">                        <b>DEFECTIVE AEC RECEPTOR</b></p>
<p><b> </b> EQUIPMENT INSPECTED</p>
<p> Manufacturer:  Lorad</p>
<p> Model Number:  8-004-0017</p>
<p> Model Name:  MultiCare Platinum Breast Biopsy System</p>
<p> Serial Number:  6112053132</p>
<p> Date of Manufacturer:  December 2005</p>
<p> Description:         This is a state-of-the-art breast biopsy system designed for prone stereotaxis, precise lesion localization, and accurate needle placement. The unit is a fully controllable system with manual x-ray control and AEC. The lesion coordinates are calculated using the Digital Spot Mammography (DSM) system. Refer to inventory list for included accessories.</p>
<p> Condition: Very Good Condition     </p>
]]></content:encoded>
					
					<wfw:commentRss>https://rsti-exchange.com/products/hologic-multicare-platinum/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
