<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>C-Arm &#8211; RSTI Exchange &#8211; Engineered for Life™</title>
	<atom:link href="https://rsti-exchange.com/modalities/c-arm/feed/" rel="self" type="application/rss+xml" />
	<link>https://rsti-exchange.com</link>
	<description>Pre-owned radiological Equipment &#38; Medical Imaging Parts</description>
	<lastBuildDate>Tue, 27 Oct 2015 15:37:26 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.6.2</generator>
	<item>
		<title>Philips BV Pulsera</title>
		<link>https://rsti-exchange.com/products/philips-bv-pulsera/</link>
					<comments>https://rsti-exchange.com/products/philips-bv-pulsera/#respond</comments>
		
		<dc:creator><![CDATA[editor one]]></dc:creator>
		<pubDate>Tue, 27 Oct 2015 15:36:17 +0000</pubDate>
				<guid isPermaLink="false">https://rsti-exchange.com/?post_type=products&#038;p=3729</guid>

					<description><![CDATA[Philips BV Pulsera S/N: 297 Oct 2005 &#160; Inventory &#160; Pulsera C-Arm I. sep 2005 Tube Housing Feb 2006 X-Ray Generator Sep 2006 Monitor Cart SONY UP-990AD Printer MDVDR-100 DVD Recorder Footswitch Assy &#160; &#160; &#160; &#160;]]></description>
										<content:encoded><![CDATA[<p>Philips BV Pulsera</p>
<p>S/N: 297</p>
<p>Oct 2005</p>
<p>&nbsp;</p>
<p><strong><u>Inventory</u></strong></p>
<p>&nbsp;</p>
<p>Pulsera C-Arm</p>
<ul>
<li>I. sep 2005</li>
<li>Tube Housing Feb 2006</li>
<li>X-Ray Generator Sep 2006</li>
</ul>
<p>Monitor Cart</p>
<ul>
<li>SONY UP-990AD Printer</li>
<li>MDVDR-100 DVD Recorder</li>
<li>Footswitch Assy</li>
</ul>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rsti-exchange.com/products/philips-bv-pulsera/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>OEC 9800 NEUROVAS C-Arm</title>
		<link>https://rsti-exchange.com/products/oec-9800-neurovas-c-arm/</link>
					<comments>https://rsti-exchange.com/products/oec-9800-neurovas-c-arm/#respond</comments>
		
		<dc:creator><![CDATA[editor one]]></dc:creator>
		<pubDate>Fri, 20 Feb 2015 13:53:55 +0000</pubDate>
				<guid isPermaLink="false">https://rsti-exchange.com/?post_type=products&#038;p=3241</guid>

					<description><![CDATA[OEC 9800 NEUROVAS S/N: 82-1651 Mar 2002  Hours = 8,273  Software WS    5.7.95 GIB    4.8.22 SRV  3.1.38 FFB   4.8.22  Inventory  Series 9800 C-Arm X-ray tube (RAD-99) Insert s/n: 53718-2N Feb 2002 Image Intensifier Model: 00-881192-01 s/n: D030845 Mar 2002 H.V. &#8230; <a href="https://rsti-exchange.com/products/oec-9800-neurovas-c-arm/">Read more<span class="meta-nav">&#8230;</span></a>]]></description>
										<content:encoded><![CDATA[<p>OEC 9800 NEUROVAS</p>
<p>S/N: 82-1651</p>
<p>Mar 2002</p>
<p> Hours = 8,273</p>
<p> <b><span style="text-decoration: underline;">Software</span></b></p>
<p>WS    5.7.95</p>
<p>GIB    4.8.22</p>
<p>SRV  3.1.38</p>
<p>FFB   4.8.22</p>
<p> <b><span style="text-decoration: underline;">Inventory</span></b></p>
<p> Series 9800 C-Arm</p>
<ul>
<li><span style="text-decoration: underline;">X-ray tube (RAD-99)</span></li>
<li>Insert s/n: 53718-2N</li>
<li>Feb 2002</li>
<li><span style="text-decoration: underline;">Image Intensifier</span></li>
<li>Model: 00-881192-01</li>
<li>s/n: D030845</li>
<li>Mar 2002</li>
<li><span style="text-decoration: underline;">H.V. Generator/Control</span></li>
<li>Model: 00-881188-01</li>
<li>s/n: D030844</li>
<li>Mar 2002</li>
<li><span style="text-decoration: underline;">Beam Limiting Device</span></li>
<li>Model: 00-881190-01</li>
<li>s/n: D030843</li>
<li>Mar 2002</li>
</ul>
<p>1K x 1K Workstation</p>
<ul>
<li>Codonics EP-1660P Printer</li>
</ul>
<p>Fluoro Footswitch</p>
<p>Operator Documentation CD</p>
<p>OEC 9800 Update and Supplement Manual</p>
<h1> </h1>
<p> Description:        This C-Arm is a high quality Fluoroscopic imaging system primarily used for fluoroscopic imaging during surgical, orthopedic, critical care and emergency care procedures.  It consists of the C-Arm and a Dual Monitor Cart.  All functions of this unit are controlled by a microprocessor, and the operator is informed of any error conditions on the control panel display. Refer to inventory list for included accessories.</p>
<p>&nbsp;</p>
<p>Condition:       All C-Arm functions work according to manufacturers specifications.  It is equipped with a Codonics EP-1660P thermal printer.  This printer has a “HEAD PREHEATING” error and does not work.  The workstation has cosmetic scratches and should be repainted.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://rsti-exchange.com/products/oec-9800-neurovas-c-arm/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>OEC 9900 Elite</title>
		<link>https://rsti-exchange.com/products/oec-9900-elite/</link>
					<comments>https://rsti-exchange.com/products/oec-9900-elite/#respond</comments>
		
		<dc:creator><![CDATA[editor one]]></dc:creator>
		<pubDate>Wed, 26 Jun 2013 13:24:58 +0000</pubDate>
				<guid isPermaLink="false">http://rstiexchange.com/rstipress/?post_type=products&#038;p=1163</guid>

					<description><![CDATA[S/N: E9-1259  2010       CALL FOR PRICE]]></description>
										<content:encoded><![CDATA[<p style="font-family: Arial, Helvetica, sans-serif;">S/N: E9-1259</p>
<p style="font-family: Arial, Helvetica, sans-serif;"> 2010</p>
<p style="font-family: Arial, Helvetica, sans-serif;"> </p>
<p style="font-family: Arial, Helvetica, sans-serif;"> </p>
<p style="font-family: Arial, Helvetica, sans-serif;"> </p>
<p style="font-family: Arial, Helvetica, sans-serif;"><span style="text-decoration: underline;"><strong style="font-size: 24px; font-style: italic; color: #d82634;">CA</strong></span><strong style="font-size: 24px; font-style: italic; color: #d82634;">LL FO</strong><strong style="font-size: 24px; font-style: italic; color: #d82634;">R PRICE</strong></p>
]]></content:encoded>
					
					<wfw:commentRss>https://rsti-exchange.com/products/oec-9900-elite/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>FluoroScan Office Mate</title>
		<link>https://rsti-exchange.com/products/fluoroscan-office-mate/</link>
					<comments>https://rsti-exchange.com/products/fluoroscan-office-mate/#respond</comments>
		
		<dc:creator><![CDATA[editor one]]></dc:creator>
		<pubDate>Fri, 21 Jun 2013 18:18:31 +0000</pubDate>
				<guid isPermaLink="false">http://rstiexchange.com/rstipress/?post_type=products&#038;p=547</guid>

					<description><![CDATA[FluoroScan Office Mate Model 50600 S/n: 02-0103-03 Jan 2003 &#160; Inventory &#160; Office Mate 50600 Footswitch Power Cord Manual &#160; X-ray Tube Model: 210332 S/n: KB071802 Jul 2002 Voltage Rating: 40 to 75kVp &#160; Image Amplifier S/N: 99031189 Jan 2003 &#8230; <a href="https://rsti-exchange.com/products/fluoroscan-office-mate/">Read more<span class="meta-nav">&#8230;</span></a>]]></description>
										<content:encoded><![CDATA[<p>FluoroScan</p>
<p>Office Mate Model 50600</p>
<p>S/n: 02-0103-03</p>
<p>Jan 2003</p>
<p>&nbsp;</p>
<p><b><span style="text-decoration: underline;">Inventory</span></b></p>
<p>&nbsp;</p>
<p>Office Mate 50600</p>
<p>Footswitch</p>
<p>Power Cord</p>
<p>Manual</p>
<p>&nbsp;</p>
<ul>
<li><b><span style="text-decoration: underline;">X-ray Tube</span></b></li>
<li>Model: 210332</li>
<li>S/n: KB071802</li>
<li>Jul 2002</li>
<li>Voltage Rating: 40 to 75kVp</li>
</ul>
<p>&nbsp;</p>
<ul>
<li><b><span style="text-decoration: underline;">Image Amplifier</span></b></li>
<li>S/N: 99031189</li>
<li>Jan 2003</li>
</ul>
<p>&nbsp;</p>
<h1>INSPECTION CERTIFICATE</h1>
<p>&nbsp;</p>
<p>Inspection Date: November 10, 2011</p>
<p>&nbsp;</p>
<h1>EQUIPMENT INSPECTED</h1>
<p>&nbsp;</p>
<p>Manufacturer:  FluoroScan</p>
<p>&nbsp;</p>
<p>Model Number:   50600</p>
<p>&nbsp;</p>
<p>Model Name: Office Mate</p>
<p>&nbsp;</p>
<p>Serial Number:  02-0103-03</p>
<p>&nbsp;</p>
<p>Date of Manufacturer:  Jan 2003</p>
<p>&nbsp;</p>
<p>Description:         The FluoroScan Imaging System is used for a variety of diagnostic, surgical, and postoperative procedures for the extremities, including the knee and shoulder.   The Office Mate X-Ray beam is tightly collimated and heavily filtered, and is designed to operate at maximum tube current levels of 0.100 mA.</p>
<p>&nbsp;</p>
<p>Condition:       Very Good condition with a few cosmetic scratches.   All functions were tested and perform to manufacturers specifications.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>